🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

700 Amp Wire Size at 120 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 700 A load over a 120 ft (36.6 m) one-way run.

Copper Wire (≤3% Drop)7× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.57%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 3.57V (29.73%)
Voltage at Load End11.7 VLoss: 0.31 V (216.3 W)
Power & Breaker (125%)8.4 kW1000A Breaker Recommended

All AWG & kcmil Wire Gauges for 700 Amps at 120 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A526.84 V (4390.29%)0.0 V869.03 V (7241.93%)368784.6 WDrop/Amp High
12 AWG3.31 mm²20 A331.06 V (2758.85%)0.0 V546.1 V (4550.82%)231743.8 WDrop/Amp High
10 AWG5.26 mm²30 A208.33 V (1736.09%)0.0 V343.65 V (2863.73%)145831.2 WDrop/Amp High
8 AWG8.37 mm²50 A130.92 V (1091.02%)0.0 V215.96 V (1799.67%)91645.4 WDrop/Amp High
6 AWG13.3 mm²65 A82.39 V (686.6%)0.0 V135.91 V (1132.57%)57674.6 WDrop/Amp High
4 AWG21.15 mm²85 A51.81 V (431.76%)0.0 V85.47 V (712.21%)36268.2 WDrop/Amp High
3 AWG26.67 mm²100 A41.09 V (342.4%)0.0 V67.78 V (564.8%)28761.6 WDrop/Amp High
2 AWG33.62 mm²115 A32.59 V (271.62%)0.0 V53.77 V (448.04%)22815.9 WDrop/Amp High
1 AWG42.41 mm²130 A25.84 V (215.32%)0.0 V42.62 V (355.18%)18087.1 WDrop/Amp High
1/0 AWG53.49 mm²150 A20.49 V (170.72%)0.0 V33.79 V (281.61%)14340.5 WDrop/Amp High
2/0 AWG67.43 mm²175 A16.25 V (135.43%)0.0 V26.81 V (223.39%)11375.8 WDrop/Amp High
3/0 AWG85.01 mm²200 A12.89 V (107.42%)0.0 V21.26 V (177.19%)9023.3 WDrop/Amp High
4/0 AWG107.2 mm²230 A10.22 V (85.18%)1.8 V16.86 V (140.52%)7155.5 WDrop/Amp High
250 kcmil126.7 mm²255 A8.65 V (72.07%)3.4 V14.27 V (118.89%)6054.2 WDrop/Amp High
300 kcmil152.0 mm²285 A7.21 V (60.08%)4.8 V11.89 V (99.1%)5046.5 WDrop/Amp High
350 kcmil177.3 mm²310 A6.18 V (51.5%)5.8 V10.2 V (84.96%)4326.4 WDrop/Amp High
400 kcmil202.7 mm²335 A5.41 V (45.05%)6.6 V8.92 V (74.31%)3784.3 WDrop/Amp High
500 kcmil253.4 mm²380 A4.32 V (36.04%)7.7 V7.13 V (59.44%)3027.1 WDrop/Amp High
600 kcmil304.0 mm²420 A3.6 V (30.04%)8.4 V5.95 V (49.55%)2523.3 WDrop/Amp High
750 kcmil380.0 mm²475 A2.88 V (24.03%)9.1 V4.76 V (39.64%)2018.6 WDrop/Amp High
1000 kcmil506.7 mm²545 A2.16 V (18.02%)9.8 V3.57 V (29.73%)1513.9 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 700 amps at 120 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 700A load over 120 feet one-way at 12V (DC), you need 7× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.31V (2.57%) and delivers 11.7V at the load.

What size aluminum wire is required for 700 amps at 120 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 3.57V (29.73%).

What breaker size is needed for a 700A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (700A × 1.25 = 875.0A), which corresponds to a standard 1000A circuit breaker.