425 Amp Wire Size at 300 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 425 A load over a 300 ft (91.4 m) one-way run.

Copper Wire (≤3% Drop)10× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.74%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 5.41V (45.12%)
Voltage at Load End11.7 VLoss: 0.33 V (139.5 W)
Power & Breaker (125%)5.1 kW600A Breaker Recommended

All AWG & kcmil Wire Gauges for 425 Amps at 300 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A799.66 V (6663.84%)0.0 V1319.07 V (10992.22%)339855.7 WDrop/Amp High
12 AWG3.31 mm²20 A502.51 V (4187.55%)0.0 V828.9 V (6907.5%)213564.9 WDrop/Amp High
10 AWG5.26 mm²30 A316.22 V (2635.13%)0.0 V521.61 V (4346.73%)134391.6 WDrop/Amp High
8 AWG8.37 mm²50 A198.72 V (1656.01%)0.0 V327.8 V (2731.64%)84456.4 WDrop/Amp High
6 AWG13.3 mm²65 A125.06 V (1042.16%)0.0 V206.29 V (1719.08%)53150.4 WDrop/Amp High
4 AWG21.15 mm²85 A78.64 V (655.36%)0.0 V129.72 V (1081.03%)33423.2 WDrop/Amp High
3 AWG26.67 mm²100 A62.37 V (519.71%)0.0 V102.87 V (857.29%)26505.4 WDrop/Amp High
2 AWG33.62 mm²115 A49.47 V (412.28%)0.0 V81.61 V (680.07%)21026.2 WDrop/Amp High
1 AWG42.41 mm²130 A39.22 V (326.83%)0.0 V64.69 V (539.11%)16668.2 WDrop/Amp High
1/0 AWG53.49 mm²150 A31.1 V (259.13%)0.0 V51.29 V (427.44%)13215.6 WDrop/Amp High
2/0 AWG67.43 mm²175 A24.67 V (205.56%)0.0 V40.69 V (339.07%)10483.5 WDrop/Amp High
3/0 AWG85.01 mm²200 A19.57 V (163.05%)0.0 V32.27 V (268.95%)8315.5 WDrop/Amp High
4/0 AWG107.2 mm²230 A15.52 V (129.3%)0.0 V25.59 V (213.28%)6594.2 WDrop/Amp High
250 kcmil126.7 mm²255 A13.13 V (109.4%)0.0 V21.65 V (180.46%)5579.3 WDrop/Amp High
300 kcmil152.0 mm²285 A10.94 V (91.19%)1.1 V18.05 V (150.42%)4650.7 WDrop/Amp High
350 kcmil177.3 mm²310 A9.38 V (78.18%)2.6 V15.47 V (128.96%)3987.0 WDrop/Amp High
400 kcmil202.7 mm²335 A8.21 V (68.38%)3.8 V13.54 V (112.8%)3487.4 WDrop/Amp High
500 kcmil253.4 mm²380 A6.56 V (54.7%)5.4 V10.83 V (90.23%)2789.7 WDrop/Amp High
600 kcmil304.0 mm²420 A5.47 V (45.59%)6.5 V9.03 V (75.21%)2325.3 WDrop/Amp High
750 kcmil380.0 mm²475 A4.38 V (36.48%)7.6 V7.22 V (60.17%)1860.3 WDrop/Amp High
1000 kcmil506.7 mm²545 A3.28 V (27.36%)8.7 V5.41 V (45.12%)1395.1 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 425 amps at 300 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 425A load over 300 feet one-way at 12V (DC), you need 10× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.33V (2.74%) and delivers 11.7V at the load.

What size aluminum wire is required for 425 amps at 300 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 5.41V (45.12%).

What breaker size is needed for a 425A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (425A × 1.25 = 531.2A), which corresponds to a standard 600A circuit breaker.