425 Amp Wire Size at 120 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 425 A load over a 120 ft (36.6 m) one-way run.

Copper Wire (≤3% Drop)4× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.73%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 2.17V (18.05%)
Voltage at Load End11.7 VLoss: 0.33 V (139.5 W)
Power & Breaker (125%)5.1 kW600A Breaker Recommended

All AWG & kcmil Wire Gauges for 425 Amps at 120 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A319.86 V (2665.53%)0.0 V527.63 V (4396.89%)135942.3 WDrop/Amp High
12 AWG3.31 mm²20 A201.0 V (1675.02%)0.0 V331.56 V (2763.0%)85426.0 WDrop/Amp High
10 AWG5.26 mm²30 A126.49 V (1054.05%)0.0 V208.64 V (1738.69%)53756.6 WDrop/Amp High
8 AWG8.37 mm²50 A79.49 V (662.4%)0.0 V131.12 V (1092.66%)33782.5 WDrop/Amp High
6 AWG13.3 mm²65 A50.02 V (416.87%)0.0 V82.52 V (687.63%)21260.1 WDrop/Amp High
4 AWG21.15 mm²85 A31.46 V (262.14%)0.0 V51.89 V (432.41%)13369.3 WDrop/Amp High
3 AWG26.67 mm²100 A24.95 V (207.89%)0.0 V41.15 V (342.91%)10602.2 WDrop/Amp High
2 AWG33.62 mm²115 A19.79 V (164.91%)0.0 V32.64 V (272.03%)8410.5 WDrop/Amp High
1 AWG42.41 mm²130 A15.69 V (130.73%)0.0 V25.88 V (215.65%)6667.3 WDrop/Amp High
1/0 AWG53.49 mm²150 A12.44 V (103.65%)0.0 V20.52 V (170.98%)5286.2 WDrop/Amp High
2/0 AWG67.43 mm²175 A9.87 V (82.22%)2.1 V16.28 V (135.63%)4193.4 WDrop/Amp High
3/0 AWG85.01 mm²200 A7.83 V (65.22%)4.2 V12.91 V (107.58%)3326.2 WDrop/Amp High
4/0 AWG107.2 mm²230 A6.21 V (51.72%)5.8 V10.24 V (85.31%)2637.7 WDrop/Amp High
250 kcmil126.7 mm²255 A5.25 V (43.76%)6.7 V8.66 V (72.18%)2231.7 WDrop/Amp High
300 kcmil152.0 mm²285 A4.38 V (36.48%)7.6 V7.22 V (60.17%)1860.3 WDrop/Amp High
350 kcmil177.3 mm²310 A3.75 V (31.27%)8.2 V6.19 V (51.58%)1594.8 WDrop/Amp High
400 kcmil202.7 mm²335 A3.28 V (27.35%)8.7 V5.41 V (45.12%)1395.0 WDrop/Amp High
500 kcmil253.4 mm²380 A2.63 V (21.88%)9.4 V4.33 V (36.09%)1115.9 WDrop/Amp High
600 kcmil304.0 mm²420 A2.19 V (18.24%)9.8 V3.61 V (30.08%)930.1 WDrop/Amp High
750 kcmil380.0 mm²475 A1.75 V (14.59%)10.2 V2.89 V (24.07%)744.1 WDrop/Amp High
1000 kcmil506.7 mm²545 A1.31 V (10.94%)10.7 V2.17 V (18.05%)558.0 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 425 amps at 120 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 425A load over 120 feet one-way at 12V (DC), you need 4× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.33V (2.73%) and delivers 11.7V at the load.

What size aluminum wire is required for 425 amps at 120 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 2.17V (18.05%).

What breaker size is needed for a 425A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (425A × 1.25 = 531.2A), which corresponds to a standard 600A circuit breaker.