⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-24)
🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

425 Amp Wire Size at 125 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 425 A load over a 125 ft (38.1 m) one-way run.

Copper Wire (≤3% Drop)4× 1000 kcmil (Parallel)506.7 mm² · Drop: 2.85%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 2.26V (18.8%)
Voltage at Load End11.7 VLoss: 0.34 V (145.3 W)
Power & Breaker (125%)5.1 kW600A Breaker Recommended

All AWG & kcmil Wire Gauges for 425 Amps at 125 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A333.19 V (2776.6%)0.0 V549.61 V (4580.09%)141606.5 WDrop/Amp High
12 AWG3.31 mm²20 A209.38 V (1744.81%)0.0 V345.37 V (2878.12%)88985.4 WDrop/Amp High
10 AWG5.26 mm²30 A131.76 V (1097.97%)0.0 V217.34 V (1811.14%)55996.5 WDrop/Amp High
8 AWG8.37 mm²50 A82.8 V (690.0%)0.0 V136.58 V (1138.18%)35190.2 WDrop/Amp High
6 AWG13.3 mm²65 A52.11 V (434.23%)0.0 V85.95 V (716.28%)22146.0 WDrop/Amp High
4 AWG21.15 mm²85 A32.77 V (273.07%)0.0 V54.05 V (450.43%)13926.3 WDrop/Amp High
3 AWG26.67 mm²100 A25.99 V (216.55%)0.0 V42.86 V (357.2%)11043.9 WDrop/Amp High
2 AWG33.62 mm²115 A20.61 V (171.78%)0.0 V34.0 V (283.36%)8760.9 WDrop/Amp High
1 AWG42.41 mm²130 A16.34 V (136.18%)0.0 V26.96 V (224.63%)6945.1 WDrop/Amp High
1/0 AWG53.49 mm²150 A12.96 V (107.97%)0.0 V21.37 V (178.1%)5506.5 WDrop/Amp High
2/0 AWG67.43 mm²175 A10.28 V (85.65%)1.7 V16.95 V (141.28%)4368.1 WDrop/Amp High
3/0 AWG85.01 mm²200 A8.15 V (67.94%)3.8 V13.45 V (112.06%)3464.8 WDrop/Amp High
4/0 AWG107.2 mm²230 A6.46 V (53.87%)5.5 V10.66 V (88.87%)2747.6 WDrop/Amp High
250 kcmil126.7 mm²255 A5.47 V (45.58%)6.5 V9.02 V (75.19%)2324.7 WDrop/Amp High
300 kcmil152.0 mm²285 A4.56 V (38.0%)7.4 V7.52 V (62.67%)1937.8 WDrop/Amp High
350 kcmil177.3 mm²310 A3.91 V (32.57%)8.1 V6.45 V (53.73%)1661.3 WDrop/Amp High
400 kcmil202.7 mm²335 A3.42 V (28.49%)8.6 V5.64 V (47.0%)1453.1 WDrop/Amp High
500 kcmil253.4 mm²380 A2.73 V (22.79%)9.3 V4.51 V (37.6%)1162.4 WDrop/Amp High
600 kcmil304.0 mm²420 A2.28 V (19.0%)9.7 V3.76 V (31.34%)968.9 WDrop/Amp High
750 kcmil380.0 mm²475 A1.82 V (15.2%)10.2 V3.01 V (25.07%)775.1 WDrop/Amp High
1000 kcmil506.7 mm²545 A1.37 V (11.4%)10.6 V2.26 V (18.8%)581.3 WDrop/Amp High

Frequently Asked Engineering Questions

What size copper wire do I need for 425 amps at 125 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 425A load over 125 feet one-way at 12V (DC), you need 4× 1000 kcmil (Parallel) copper wire. This produces a voltage drop of 0.34V (2.85%) and delivers 11.7V at the load.

What size aluminum wire is required for 425 amps at 125 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 2.26V (18.8%).

What breaker size is needed for a 425A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (425A × 1.25 = 531.2A), which corresponds to a standard 600A circuit breaker.