⚡ Cu ρ (75°C): 0.0214 Ω·mm²/m 🔌 NEC / IEC Standards: NFPA 70 & IEC 60364 🇺🇸 US Grid Avg: $0.175/kWh 🇩🇪 DE Grid Avg: €0.345/kWh 🇸🇪 SE Elpris: 1.54 SEK/kWh 🇳🇴 NO Strøm: 1.17 NOK/kWh 🔩 Copper Ref: $9,650/t (2026-10-25)
⚡ IEC 60364-5-52 · DIN VDE · NEK 400 · SS 436 40 00

325 Amp Cable Size at 250 Meters (24V DC (Off-Grid Solar / Industrial Control))

IEC 60364-5-52 metric conductor sizing (mm²), voltage drop, and power loss calculation for 325 A over 250 m (820.2 ft).

Copper Cable (≤3% Drop)13× 400 mm²Drop: 0.67V (2.79%)
Aluminum Cable (≤3% Drop)400 mm²Drop: 14.34V (59.75%)
Voltage at Load23.3 VLine Loss: 217.3 W
Max Power & Breaker7.8 kW350A MCB/MCCB

IEC 60364 Cable Cross-Section Table (1.5 mm² – 400 mm²) for 325A at 250m

Cross-Section (mm²)Cu AmpacityAl Ampacity Cu Voltage DropLoad VoltageAl Voltage DropPower LossStatus
1.5 mm²16 A12 A2318.33 V (9659.72%)0.0 V3824.17 V (15934.03%)753458.3 WDrop High
2.5 mm²24 A18 A1391.0 V (5795.83%)0.0 V2294.5 V (9560.42%)452075.0 WDrop High
4 mm²32 A25 A869.37 V (3622.4%)0.0 V1434.06 V (5975.26%)282546.9 WDrop High
6 mm²41 A32 A579.58 V (2414.93%)0.0 V956.04 V (3983.51%)188364.6 WDrop High
10 mm²57 A44 A347.75 V (1448.96%)0.0 V573.62 V (2390.1%)113018.7 WDrop High
16 mm²76 A59 A217.34 V (905.6%)0.0 V358.52 V (1493.82%)70636.7 WDrop High
25 mm²101 A78 A139.1 V (579.58%)0.0 V229.45 V (956.04%)45207.5 WDrop High
35 mm²125 A97 A99.36 V (413.99%)0.0 V163.89 V (682.89%)32291.1 WDrop High
50 mm²151 A118 A69.55 V (289.79%)0.0 V114.72 V (478.02%)22603.8 WDrop High
70 mm²192 A150 A49.68 V (206.99%)0.0 V81.95 V (341.44%)16145.5 WDrop High
95 mm²232 A181 A36.61 V (152.52%)0.0 V60.38 V (251.59%)11896.7 WDrop High
120 mm²269 A210 A28.98 V (120.75%)0.0 V47.8 V (199.18%)9418.2 WDrop High
150 mm²309 A241 A23.18 V (96.6%)0.8 V38.24 V (159.34%)7534.6 WDrop High
185 mm²353 A275 A18.8 V (78.32%)5.2 V31.01 V (129.19%)6109.1 WDrop High
240 mm²415 A324 A14.49 V (60.37%)9.5 V23.9 V (99.59%)4709.1 WDrop High
300 mm²477 A372 A11.59 V (48.3%)12.4 V19.12 V (79.67%)3767.3 WDrop High
400 mm²570 A445 A8.69 V (36.22%)15.3 V14.34 V (59.75%)2825.5 WDrop High

FAQ — 325 Amp Cable Size at 250 Meters (24V DC (Off-Grid Solar / Industrial Control))

What mm² cable size is required for 325A at 250 meters (24V)?

According to IEC 60364-5-52 ampacity and the 3% maximum voltage drop standard, you need 13× 400 mm² copper cable for 325A over 250m at 24V (voltage drop: 0.67V or 2.79%).

What is the power capacity of 325A at 24V?

At unity power factor, 325A at 24V supports 7.8 kW with a standard 350A circuit breaker.