🇺🇸 NEC NFPA 70 · Table 310.16 (75°C) · Voltage Drop Analysis

35 Amp Wire Size at 80 Feet (12V DC (Solar / Automotive / Marine))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 35 A load over a 80 ft (24.4 m) one-way run.

Copper Wire (≤3% Drop)4/0 AWG107.2 mm² · Drop: 2.84%
Aluminum Wire (≤3% Drop)350 kcmilDrop: 0.34V (2.83%)
Voltage at Load End11.7 VLoss: 0.34 V (11.9 W)
Power & Breaker (125%)0.42 kW45A Breaker Recommended

All AWG & kcmil Wire Gauges for 35 Amps at 80 Feet (12V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A17.56 V (146.34%)0.0 V28.97 V (241.4%)614.6 WDrop/Amp High
12 AWG3.31 mm²20 A11.04 V (91.96%)1.0 V18.2 V (151.69%)386.2 WDrop/Amp High
10 AWG5.26 mm²30 A6.94 V (57.87%)5.1 V11.45 V (95.46%)243.1 WDrop/Amp High
8 AWG8.37 mm²50 A4.36 V (36.37%)7.6 V7.2 V (59.99%)152.7 WDrop/Amp High
6 AWG13.3 mm²65 A2.75 V (22.89%)9.3 V4.53 V (37.75%)96.1 WDrop/Amp High
4 AWG21.15 mm²85 A1.73 V (14.39%)10.3 V2.85 V (23.74%)60.4 WDrop/Amp High
3 AWG26.67 mm²100 A1.37 V (11.41%)10.6 V2.26 V (18.83%)47.9 WDrop/Amp High
2 AWG33.62 mm²115 A1.09 V (9.05%)10.9 V1.79 V (14.93%)38.0 WDrop/Amp High
1 AWG42.41 mm²130 A0.86 V (7.18%)11.1 V1.42 V (11.84%)30.1 WDrop/Amp High
1/0 AWG53.49 mm²150 A0.68 V (5.69%)11.3 V1.13 V (9.39%)23.9 WDrop/Amp High
2/0 AWG67.43 mm²175 A0.54 V (4.51%)11.5 V0.89 V (7.45%)19.0 W~ ≤5%
3/0 AWG85.01 mm²200 A0.43 V (3.58%)11.6 V0.71 V (5.91%)15.0 W~ ≤5%
4/0 AWG107.2 mm²230 A0.34 V (2.84%)11.7 V0.56 V (4.68%)11.9 W✓ PASS (≤3%)
250 kcmil126.7 mm²255 A0.29 V (2.4%)11.7 V0.48 V (3.96%)10.1 W✓ PASS (≤3%)
300 kcmil152.0 mm²285 A0.24 V (2.0%)11.8 V0.4 V (3.3%)8.4 W✓ PASS (≤3%)
350 kcmil177.3 mm²310 A0.21 V (1.72%)11.8 V0.34 V (2.83%)7.2 W✓ PASS (≤3%)
400 kcmil202.7 mm²335 A0.18 V (1.5%)11.8 V0.3 V (2.48%)6.3 W✓ PASS (≤3%)
500 kcmil253.4 mm²380 A0.14 V (1.2%)11.9 V0.24 V (1.98%)5.0 W✓ PASS (≤3%)
600 kcmil304.0 mm²420 A0.12 V (1.0%)11.9 V0.2 V (1.65%)4.2 W✓ PASS (≤3%)
750 kcmil380.0 mm²475 A0.1 V (0.8%)11.9 V0.16 V (1.32%)3.4 W✓ PASS (≤3%)
1000 kcmil506.7 mm²545 A0.07 V (0.6%)11.9 V0.12 V (0.99%)2.5 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 35 amps at 80 feet (12V)?

To stay within the NEC recommended 3% maximum voltage drop for a 35A load over 80 feet one-way at 12V (DC), you need 4/0 AWG copper wire. This produces a voltage drop of 0.34V (2.84%) and delivers 11.7V at the load.

What size aluminum wire is required for 35 amps at 80 feet?

Using aluminum conductors (75°C rating), you should use 350 kcmil to maintain voltage drop at 0.34V (2.83%).

What breaker size is needed for a 35A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (35A × 1.25 = 43.8A), which corresponds to a standard 45A circuit breaker.