425 Amp Wire Size at 300 Feet (120V Single-Phase (US Standard Branch))

Complete conductor sizing, Ohm's law voltage drop, $I^2R$ line power loss, and circuit breaker specification for a 425 A load over a 300 ft (91.4 m) one-way run.

Copper Wire (≤3% Drop)1000 kcmil506.7 mm² · Drop: 2.74%
Aluminum Wire (≤3% Drop)1000 kcmilDrop: 5.41V (4.51%)
Voltage at Load End116.7 VLoss: 3.28 V (1395.1 W)
Power & Breaker (125%)51.0 kW600A Breaker Recommended

All AWG & kcmil Wire Gauges for 425 Amps at 300 Feet (120V)

Wire GaugeMetric AreaNEC 75°C Cu Ampacity Copper Voltage DropLoad VoltageAluminum DropLine Loss ($I^2R$)NEC Status
14 AWG2.08 mm²15 A799.66 V (666.38%)0.0 V1319.07 V (1099.22%)339855.7 WDrop/Amp High
12 AWG3.31 mm²20 A502.51 V (418.75%)0.0 V828.9 V (690.75%)213564.9 WDrop/Amp High
10 AWG5.26 mm²30 A316.22 V (263.51%)0.0 V521.61 V (434.67%)134391.6 WDrop/Amp High
8 AWG8.37 mm²50 A198.72 V (165.6%)0.0 V327.8 V (273.16%)84456.4 WDrop/Amp High
6 AWG13.3 mm²65 A125.06 V (104.22%)0.0 V206.29 V (171.91%)53150.4 WDrop/Amp High
4 AWG21.15 mm²85 A78.64 V (65.54%)41.4 V129.72 V (108.1%)33423.2 WDrop/Amp High
3 AWG26.67 mm²100 A62.37 V (51.97%)57.6 V102.87 V (85.73%)26505.4 WDrop/Amp High
2 AWG33.62 mm²115 A49.47 V (41.23%)70.5 V81.61 V (68.01%)21026.2 WDrop/Amp High
1 AWG42.41 mm²130 A39.22 V (32.68%)80.8 V64.69 V (53.91%)16668.2 WDrop/Amp High
1/0 AWG53.49 mm²150 A31.1 V (25.91%)88.9 V51.29 V (42.74%)13215.6 WDrop/Amp High
2/0 AWG67.43 mm²175 A24.67 V (20.56%)95.3 V40.69 V (33.91%)10483.5 WDrop/Amp High
3/0 AWG85.01 mm²200 A19.57 V (16.3%)100.4 V32.27 V (26.9%)8315.5 WDrop/Amp High
4/0 AWG107.2 mm²230 A15.52 V (12.93%)104.5 V25.59 V (21.33%)6594.2 WDrop/Amp High
250 kcmil126.7 mm²255 A13.13 V (10.94%)106.9 V21.65 V (18.05%)5579.3 WDrop/Amp High
300 kcmil152.0 mm²285 A10.94 V (9.12%)109.1 V18.05 V (15.04%)4650.7 WDrop/Amp High
350 kcmil177.3 mm²310 A9.38 V (7.82%)110.6 V15.47 V (12.9%)3987.0 WDrop/Amp High
400 kcmil202.7 mm²335 A8.21 V (6.84%)111.8 V13.54 V (11.28%)3487.4 WDrop/Amp High
500 kcmil253.4 mm²380 A6.56 V (5.47%)113.4 V10.83 V (9.02%)2789.7 WDrop/Amp High
600 kcmil304.0 mm²420 A5.47 V (4.56%)114.5 V9.03 V (7.52%)2325.3 WDrop/Amp High
750 kcmil380.0 mm²475 A4.38 V (3.65%)115.6 V7.22 V (6.02%)1860.3 W~ ≤5%
1000 kcmil506.7 mm²545 A3.28 V (2.74%)116.7 V5.41 V (4.51%)1395.1 W✓ PASS (≤3%)

Frequently Asked Engineering Questions

What size copper wire do I need for 425 amps at 300 feet (120V)?

To stay within the NEC recommended 3% maximum voltage drop for a 425A load over 300 feet one-way at 120V (1-Phase), you need 1000 kcmil copper wire. This produces a voltage drop of 3.28V (2.74%) and delivers 116.7V at the load.

What size aluminum wire is required for 425 amps at 300 feet?

Using aluminum conductors (75°C rating), you should use 1000 kcmil to maintain voltage drop at 5.41V (4.51%).

What breaker size is needed for a 425A continuous load?

Under NEC 210.20(A), continuous loads require a circuit breaker rated at 125% of the continuous current (425A × 1.25 = 531.2A), which corresponds to a standard 600A circuit breaker.